Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual  REFLEX RR B,E RR B,E CC 41-  9
Positioning equipment – 9390
Assembly of height pre-set
41.8  Assembly of height pre-set
• Undo the 11 screws holding the lower panel in place and remove it.
• Undo the plastic rivets and remove the plastic console from the cav-
ity for height pre-set.
• Screw the height pre-set into place.
• Reconnect the connector.
• Screw the lower panel back into place with the 11 screws.
41.9  Programming
• Press the PROG button briefly to enter programming mode. The 
LED in the button comes on and the display shows PL00 when the 
programming routine has been started. You can now program new 
lifting heights, modify or delete programmed values.
41.9.1 Programming a level
You can only program lifting heights in the main lift range.
NOTE! 
Forks not horizontal.
The load may slide off the forks or catch on the rack.
The forks must always be horizontal, particularly when the load is be-
ing deposited on or collected from the rack.
Collect level
• Enter programming mode and state the required level (e.g. 1+5= 
level 15). The numbers are shown on the display.
• Lift the forks to the required level and press the button COLLECT. 
The LED flashes.