T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
39-  14 Service Manual  REFLEX  RR B/E, RR B/E CC © BT Europe AB
Control/computer equipment – 8700
Other menu functions
39.10  Other menu functions
39.10.1 Save to file
The truck parameters can be saved in the PC for loading at a later date. 
Select <File | Save to file | Parameters >. All parameters in the nodes 
that are connected to the bus will be read and saved in a file.
 
If only the hour meters are required, select <File | Save to file | Hour 
meters >.
39.10.2 Loading from a file
A set of parameters can be loaded from the PC to the truck. Select <File 
| Load from file | Parameters >. The parameters in the file will be copied 
to the nodes connected to the bus. If only the hour meter settings are 
required, select <File | Load from file | Hour meters >.
39.10.3 Resetting the CAN adapter
If problems arise when resetting the CAN adapter connected to the PC, 
this can be done manually by confirming there is voltage to the adapter 
and then selecting <Nodes | Reset CPC-PP >. 
39.10.4 Deleting the fault code log
In order to delete the truck's fault code log, start the truck in parameter 
mode and then select < Tools | Erase error log >.
39.10.5 Resetting the hour meter
In order to zero the truck’s hour meter, start the truck in drive mode and 
then select < Tools | Reset hour meters >.
39.10.6 Reading the fault code log
In order to display the truck’s fault code log, select < Tools | Read error log 
>.
39.10.7 Adjusting the date/time
In order to rapidly adjust the truck’s date and time, select < Tools | 
Adjust date & time >. The time specified on the PC will now be down
-
loaded into the truck.
NOTE!
NOT trucks without a real time clock.
https://www.forkliftpdfmanuals.com/