T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
25-  102 Service Manual  REFLEX RR B/E, RR B/E CC © BT Europe AB
Keypad
Programming
25.3.4 Function 3
• Connection 1 and 2 (X3:5, X3:9) is connected to system negative.
• Test function for relay 
Designate the code 1234567890 and green pushbutton to close the 
relay in the keypad.
• Open the relay with red pushbutton
Not. 1 If the service CAN-key is used at log-in no driver PIN-code is 
necessary to designate.
25.4  Programming
25.4.1 LED status
Log-in
At programming
Function Green LED Red LED
Pushbutton 0-9 is used Illuminate when pushbutton is 
depressed.
Log-out Illuminates ~0,8 
sek
Relay in keypad is closed Illuminates with brightness.
Incorrect driver PIN-code designated Illuminates ~0,8 
sek
Function Green LED Red LED
Keypad in programming mode Illuminates for ~0,8 seconds 
and then flashes with interval 
of 2 seconds.
Pushbutton 0-9 is used Illuminates when pushbutton 
is depressed.
Correct value designated Illuminates ~0,8 sek
Incorrect value designated Illuminates ~0,8 
sek