T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 4 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Terminal connections and voltages on A5
24.2.4 40X
24.2.5 50X
Term. Cable Description Active
(V)
LED
401 117 CAN – Serial (+) +15
402 118 CAN – Serial (-) 0
403 119 CAN H 0-5
404 120 CAN L 0-5
405 121 RS485 - Serial (+)
406 122 RS485 - Serial (-)
407 125 RS485 - TX (+), transmits data
408 126 RS485 - TX (-), transmits data
409 127 RS485 - RX (+), receives data
410 128 RS485 - RX (-), receives data
411 65 Pressure transducer, load weighing 0,5-4,5
Term. Cable Description Active
(V)
LED
501 50 Potentiometer acceleration, set point +3,7–1,7
502 51 Potentiometer braking, set point +1,7–4,1
503 82 Potentiometer acceleration, set point +0,66–3,7–6,6
504 83 Potentiometer extension/retraction of mast,
set point
+0,66–3,7–6,6
505 84 Potentiometer tilting of forks, set point +0,66–3,7–6,6
506 85 Potentiometer extra (1) hydraulic function, set
point
+0,66–3,7–6,6
507 27 Potentiometer feed +7,35
508 28 Minus to 501-506, 510 0
509 62 Steering tachometer (+) Max. ±3
510 86 Potentiometer extra (2) hydraulic function, set
point
+0,66–3,7–6,6
511 129 Steering tachometer (-) 0