T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
41- 10 Service Manual REFLEX RR B,E RR B,E CC © BT Europe AB
Positioning equipment – 9390
Programming
Leave level
Pick up the load and wait three seconds. Lift the forks just enough so
that the load can be removed from the rack. Ensure that there is suf
-
ficient space for safe handling.
Now press the LEAVE button and both LEDs for collecting and leav-
ing will start to flash..
Press the PROG button until both LEDs go out and the display indi-
cates PL00, to save the information.
Repeat from “LEAVE “ level to program more levels.
Press the STOP button to return to display mode.
41.9.2 Deleting programmed levels
Lower the forks to free lift level when deleting programmed lifting
heights.
Enter programming mode and state the required level (e.g. 1+5=
level 15). The numbers are shown on the display.
Press the COLLECT button (the LED flashes) and then press the
LEAVE button (both LEDs start to flash).
Press the PROG button until both LEDs (COLLECT and LEAVE)
stop flashing and the display shows PL00 to erase the memory.
Press the STOP button to return to display mode.