Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 17
Electronic card – 5710
Parameter setting of all parameters
24.5.12 Parameter 19
24.5.13 Parameter 20
Use this parameter to set whether operating hours, A-d, S or weight
measurement shall be displayed when the truck is operated.
24.5.14 Parameter 21
Use this parameter to set the type of battery installed on the truck. This
parameter can also be used to compensate for different driving styles.
For additional information about battery installation and setting the bat-
tery parameters, please see section 5110.
When setting the battery guard check-point, perform measurement as
follows:
Specific gravity with fully charged battery. Use to inspect the battery
quality.
When the battery indicator shows 80% discharge, minimum specific
gravity is 1.14.)
Lift
height:
Rough setting
B/E 1-6 mast with inte-
grated side shift
Rough setting
B/E7-8
4400 1,42
4600 1,50
4800 1,56 1,65
5400 1,75 1,84
5700 1,85
6300 2,07 2,14
6750 2,22 2,38
7000 2,42 2,48
7500 2,56
8000 2,74 2,83
8500 2,93 3,01
9000 3,09 3,14
9500 3,19 3,27
10000 3,43
10500 3,58
10800 3,70