T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
41-  18 Service Manual  REFLEX  RR B,E RR B,E CC © BT Europe AB
Positioning equipment – 9390
Error codes
41.13  Error codes
• Four lines appear at start-up. This shows that there has been no 
communication between height pre-set and the main electronics. 
The lines will disappear when communication is restored between 
the units.
• Four dots appear on the display when the forks are in the free lift 
zone.
• If the dots are flashing, this is an indication that the reference switch 
was activated when the truck was started (e.g. the forks were above 
the free lift zone). If the dots continue to flash after the forks have 
been lowered, a fault may have occurred in the wiring or the height 
reference switch.
Error code Remarks
Err 1 Requested height level not programmed or incor-
rect
Err 2 Forks have stopped outside the tolerance zone 
(P5)
Err 9 Incorrect value entered when programming
Err flashing Fault in communication between height pre-set 
and truck computer