T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 52 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning codes with registration
Hydraulic valve Y16 engages a extra hydraulic function, e.g. side shift
or fork spread.
1. If a valve is not connected, parameter 15 must be set to 0.
Check parameter 15. See the section “Parameter setting” in
this manual.
2. Disconnect cable 94 from output 706.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 94 is intact between terminal 706 and the
terminals in X50 via X15, X17 and X29.
- Measure the coil on Y16 between the green and black cables in
X50 with an ohmmeter. Resistance approx. 150 ohm.
- Check that cable 40 is intact from X50, via X29, X17 and X14 to
the battery negative.
3. If the fault remains, replace A5.
Code 55
Description Output 706 short circuit/breakage
Error mode General error
Error cause 1. Parameter 15 >0, no valve connected
2. Faulty wiring/valve Y16
3. Defective electronic card A5
Comments
https://www.forkliftpdfmanuals.com/