T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 58 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning codes with registration
Hydraulic valve Y10/3 engages fork lowering.
1. Check that the switch S132 is open.
2. Disconnect the cable 88 from output 803.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 88 is intact between terminal 803 and the
terminals in X17 via X14.
- Measure the coil on Y10/3 between the white and black cables in
X17 with an ohmmeter. Resistance approx. 27 ohm.
- Check that cable 40 is intact from X17, via X14 to the battery neg-
ative.
3. If the fault remains, replace A5.
Code 61
Description Output 803 short circuit/breakage
Error mode General error
Error cause 1. Emergency switch Y10/3 activated
2. Faulty wiring/valve Y10/3
3. Defective electronic card A5