EasyManua.ls Logo

BT REFLEX RR B7-8C - Page 280

BT REFLEX RR B7-8C
514 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 68 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Error Codes
Main contactor, K10, coil
1. Disconnect the cable 31 from output 804.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that cable 31 is intact up until contactor K10:A2.
- Measure the coil on Y10 between A1 and A2.
Resistance approx. 150 ohm.
- Check that cable 40 is intact between contactor K10: A1 and the
battery negative and terminals in X38.
2. If the correct voltage is on input 501 and the fault remains, re-
place the A5 electronic card.
Code 106
Description Output 804 short circuit/breakage
Error mode Critical error
Error cause 1. Faulty wiring/contactor K10
2. Defective electronic card A5
Comments
https://www.forkliftpdfmanuals.com/

Table of Contents

Related product manuals