25
Technical data
6.4 Technical data of the dosing controller SE35 Batch
The technical data of the flow transmittedosing controller SE35 Batch can be restricted by the sensor-fitting
used.
▶ Please refer to the Operating Instructions of the concerned sensor-fitting.
6.4.1 Conditions of use of a SE35 Batch
Ambient temperature
• 12...36 V DC version • –10...+60°C
• 115/230 V AC version • –10...+50°C
• UL and CSA version • 0...+40°C
Air humidity
< 80%, non condensated
Protection rating
according to EN 60529
IP65,
device wired, cover lid screwed tight and cable glands
tightened
Degree of pollution (UL and CSA recognized version)
Degree 2 according to EN 61010 -1
Installation category (UL and CSA recognized version)
Category I according to UL61010-1 - Indoor use
Max. height above sea level
2000 m
6.4.2 Conformity to standards and directives of a SE35 Batch
The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination
Certificate and/or the EU Declaration of Conformity (if applicable).
UL-Certification
Finished products with variable key PU01 or PU02 are UL-certified products and comply also with the following
standards:
• UL 61010-1
• CAN/CSA-C22.2 n°61010-1
Identification on the device Certification Variable key
UL-recognized PU01
Measuring
Equipment
EXXXXXX
®
UL-listed PU02
6.4.3 Material data of a SE35 Batch
Part Material
Housing, cover, lid, nut PC
Frontfoil / Screws Polyester / Stainless steel
Cable glands PA
Identification label Polyester
English