33
Fluid installation
7 FLUID INSTALLATION
7.1 Safety instructions
Danger
Danger due to electrical voltage.
▶ If a 12...36 V DC powered version is installed either in a wet environment or outdoors, all the electrical volt-
ages must be of max. 35 V DC.
▶ Disconnect the electrical power for all the conductors and isolate it before carrying out work on the system.
▶ All equipment connected to the wall-mounted or panel version of the flow transmitter 8025 must be double
insulated in relation to the mains in accordance with IEC standard 61010-1:2010.
▶ Observe all applicable accident protection and safety regulations for electrical equipment.
Risk of injury due to high pressure in the installation.
▶ Stop the circulation of fluid, cut off the pressure and drain the pipe before loosening the process connections.
▶ Observe the fluid temperature/pressure dependency depending on the fitting used.
Risk of injury due to high fluid temperatures.
▶ Use safety gloves to handle the device.
▶ Stop the circulation of fluid and drain the pipe before loosening the process connections.
Risk of injury due to the nature of the fluid.
▶ Respect the prevailing regulations on accident prevention and safety relating to the use of aggressive fluids.
Warning
Risk of injury due to non-conforming installation.
▶ The fluid and electrical installation can only be carried out by qualified and skilled staff with the appropriate
tools.
▶ Observe mounting instructions of the fitting or sensor-fitting.
▶ Take appropriate measures to avoid unintentional activation of the installation.
Risk of injury if the fluid pressure/temperature dependency is not respected.
▶ Take account of fluid temperature-pressure dependency according to the nature of the materials the fitting is
made of (see the technical data and the operating instructions of the fitting used).
▶ Comply with the Pressure Equipment Directive 2014/68/EU.
Protect this device against electromagnetic interference, ultraviolet rays and, when installed outdoors, the
effects of the climatic conditions.
English
Type 8025 - 8035 - SE35 BATCH