Operating and functions
To interrupt the dosing, press
ENTER
: the valve connected to output DO2 and possibly the valve connected
to output DO3 close, the device state LED flashes at a 1 Hz-frequency and the DO4 output (if configured to
transmit the device state, see chap. 10.7.26) generates a 1 Hz-frequency.
CONtiNUE
RESEt
To continue the dosing via the digital inputs:
Let the DI1 digital input activated.
then send a pulse on DI4.
To continue the dosing via the navigation keys, when the digital input DI1 is activated:
display "CONTINUE" by pressing key
0......9
or ,
then press key
ENTER
.
To abort the dosing via the digital inputs:
Deactivate the DI1 digital input.
then send a pulse on DI4.
To abort the dosing via the navigation keys, when the digital input DI1 is activated:
display "RESET" by pressing key
0......9
or ,
then press key
ENTER
.
10.5 %
The counting of the dosing quantity continues.
Process level: the device is ready for a new dosing.
Fig. 54 : Interrupting the dosing, in dosing mode "EXT. REP."