12
Technical data
6. TECHNICAL DATA
6.1. Conditions of use
Ambient temperature
-10 to +60 °C (without pH or Redox probe)
Air humidity
< 85 %, non condensated
Protection rating
IP65 and IP67 with connectors plugged in and tightened and electronic
module cover fully screwed down
6.2. Conformity to standards and directives
The device conforms to the CE directives through the following standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: complying with article 3 of §3 from 97/23/CE directive. Acc. to the 97/23/CE pressure directive, the
device can only be used in the following cases (depending on max. pressure, pipe diameter and fluid):
Type of fluid Conditions
Fluid group 1, §1.3.a only DN25
Fluid group 2, § 1.3.a DN
≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1, § 1.3.b DN
≤ 25
or DN > 25 and PNxDN ≤ 2000
Fluid group 2, § 1.3.b DN
≤ 125
The UL devices conform to the following standards:
• UL 61010-1
• CAN/CSA-C22.2 n° 61010-1
English
Type 8202 ELEMENT