13
Technical data
6.3. General technical data
6.3.1. Mechanical data
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-20 0 +20 +40 +60 +80 +100 +120
T ( ° C)
P (bar)
A
PVDF
PVC
B
+140
232
217.6
203
188.6
174
159.6
145
130.6
116
101.6
87
72.5
58
43.5
29
14
0
P (psi)
PVDF
A: application range of a 8202 with a PVDF nut
B: application range of a 8202 with a PVC nut
The measures have been made at an ambient
temperature of 60 °C
P = Fluid pressure
T = Fluid temperature
Fig. 2 Fluid temperature / pressure dependency of the 8202 (without the probe) with a PVC or PVDF nut
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0 +20 +40 +60
T (°C)
P (bar)
PVC + PP
-20
232
217.6
203
188.6
174
159.6
145
130.6
116
101.6
87
72.5
58
43.5
29
14
0
P (psi)
Metal
P = Fluid pressure
T = Fluid temperature
Fig. 3 Fluid temperature / pressure dependency of the 8202 (without the probe) with a PVC nut and a metal, PVC or PP
S022 adapter
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
-20 0 +20 +40 +60 +80 +100 +140
PVC
PP
T (°C)
P (bar)
PVC + PP
+120
232
217.6
203
188.6
174
159.6
145
130.6
116
101.6
87
72.5
58
43.5
29
14
0
P (psi)
Metal
P = Fluid pressure
T = Fluid temperature
Fig. 4 Fluid temperature / pressure dependency of the 8202 (without the probe) with a PVDF nut and a metal, PVC or
PP S022 adapter
English
Type 8202 ELEMENT

Table of Contents

Other manuals for Burkert 8202 ELEMENT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Burkert 8202 ELEMENT and is the answer not in the manual?

Burkert 8202 ELEMENT Specifications

General IconGeneral
BrandBurkert
Model8202 ELEMENT
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals