32 C7000 & 7000ER Battery Analyzer V3.5
Parameter Default Settings
Charge
1.00C
(NiCd)
1.00C
(NiMH)
0.30C
(SLA)
1.00C
(Li-Ion)
Discharge 1.00C (NiCd)
1.00C (NiMH)
0.10C (SLA - Gell), 0.40C (SLA - Hawker)
1.00C (Li-Ion)
Trickle Charge Rate 5% (NiCd)
2% (NiMH)
Recondition
Discharge Rate
12% (NiCd, NiMH)
Capacity Offset
0%
Temperature Sensing Disabled (adapters without temperature sensor)
0-45
o
C (NiCd, NiMH, SLA)
5-45
o
C (Li-Ion)
Negative slope 32mV/Cell (NiCd)
16mV/Cell (NiMH)
End of Discharge 1.00V/Cell (NiCd, NiMH)
1.75V/Cell (SLA - Gell),
1.62V/Cell (SLA - Hawker)
3.00V/Cell (Li-Ion)
End of Recondition 0.40V/Cell (NiCd, NiMH)
Charge Method Rev Load 9%
Max. Standby Voltage
2.25V/Cell
(SLA - Gell),
2.35V/Cell
(SLA - Hawker)
4.05V/Cell
(Li-Ion)
Max. Charge Voltage 2.40V/Cell (SLA - Gell), 2.60V/Cell (SLA - Hawker)
4.20V/Cell (Li-Ion)
End of Charge 0.05C (SLA, Li-Ion)