0,2,"CDX01 ","01/24/2001","085140",11,"0\80"
c) Processing of the current program began (Code 11). The battery ID
is CDX01.
0,2,"CDX01 ","01/24/2001","085140",250,"2\1416\398\21",""
d) Normal processing (Code 250) of battery CDX01. The battery is
charging (process = 2), terminal voltage is 1416mV, charge current
is 398mA, and battery temperature is 21°C. Battery capacity has
not yet been determined.
0,2,"CDX01 ","01/24/2001","085456",27,"0\80", 341
e) An OhmTest was performed (Code 27). Resistance is measured at
341m.
0,2,"CDX01 ","01/24/2001","100200",250,"7\1419\-401\35","85\37"
f) Normal processing (Code 250). The battery is discharging (process =
7), terminal voltage is 1419 mV, discharge current is 401mA, and
battery temperature is 35°C. Current battery capacity is 85%;
previous capacity was 37%.
0,2,"CDX01 ","01/25/2001","090500",250,"5\1694\7\28","89\87"
g) Normal processing (Code 250). The battery is ready (process = 5),
terminal voltage is 1694 mV, charge current is 7mA (trickle
charge), and battery temperature is 28°C. Final battery capacity
achieved is 89%; previous capacity was 87%.
0,2,"CDX090 ","04/11/2001","151600",250,"35\3943\0\23","76\67"
h) Normal processing (Code 250) of battery ID CDX090. A QuickTest
has been completed (status code 35). Terminal voltage is
3943mV, no current is being applied, and battery temperature is
23° C. The battery SoH is 76% with a confidence grade of 67, the
ASCII code for “C”. (“A” is 65, and “B” is 66).