Default Extended C-code for SLA Batteries
Parameter Default Setting
Charge
0.30 C
Discharge
0.10 C
Temperature Sensing
0 C – 45 C
Max. Standby Voltage
2.25V/cell
Max. Charge Voltage
2.40V/cell
End of Charge
0.05 C
End-Of-Discharge
1.75V/cell
Default Extended C-code for Li-ion Batteries
Parameter Default Setting
Charge
1.00 C
Discharge
1.00 C
Temperature Sensing
0 C – 45 C
Max. Standby Voltage
4.05V/cell
Max. Charge Voltage
4.20V/cell
End of Charge
0.05 C
End-Of-Discharge
3.00V/cell
Default Extended C-code for Li-Ph Batteries
Parameter Default Setting
Charge
1.00 C
Discharge
1.00 C
Temperature Sensing
0 C – 45 C
Max. Standby Voltage
3.45V/cell