Default Extended C-code for NiCd Batteries
Parameter Default Setting
Charge
1.00 C
Trickle
5%
Discharge
1.00 C
Recondition
12%
Temperature Sensing
0ºC – 45 C
Negative Slope
8mV/cell (16mV/cell for 1.2V and 2.4V
batteries)
End-Of-Discharge
1.00V/cell
End of Recognition
0.40V/cell
Charge Method
Reverse Load 9%
Default Extended C-code for NiMH Batteries
Parameter Default Setting
Charge
1.00 C
Trickle
2%
Discharge
1.00 C
Recondition
12%
Temperature Sensing
0ºC – 45 C
Negative Slope
8mV/cell, 16mV/cell for 1.2V and 2.4V
batteries
End-Of-Discharge
1.00V/cell
End of Recognition
0.40V/cell
Charge Method
Reverse Load 9%