Setting up the Data Log
To log data to a computer, connect the Cadex analyzer to the serial port of a
computer (see Connecting to BatteryShop or a Printer, page 71), set the Cadex
analyzer to log data, and set up a program to read the data from the serial port.
The procedure outlined here assumes Microsoft’s HyperTerminal communications
program is used, which comes with most versions of Microsoft Windows; however,
any compatible communications program that can read data through the computer
serial port can be used.
To set the Cadex analyzer to log data to a computer
1. From the global display, press MENU.
2. Press or to scroll to SYSTEM SETUP and then press ENTER.
3. Press or to scroll to SERIAL PORT DEVICE and then press ENTER.
4. Press or to scroll to TERMINAL and then press ENTER.
5. Press or to scroll to YES to accept changes and press ENTER.
6. Press to scroll to SERIAL PORT SETTINGS and then press ENTER.
7. Pressing or to move the cursor between options and or to
scroll through available settings, enter these serial port settings:
baud rate: 9600
handshake: none
data bits: 8
stop bits: 1
parity: none
8. Press ENTER.
9. Press or to scroll to YES to accept changes and press ENTER.
10. Press ESC twice to return to the global display.