Detailed
Message
Code Reasons Solutions
NO ADAPTER 1
No Battery Adapter is
inserted, or the inserted
adapter is not detected.
Check contacts. Clean with a
lint-free cotton swab dipped in
100% isopropyl alcohol.
NO BATTERY 10
No battery is inserted, or the
inserted battery is not
detected.
Check contacts. Turn on
battery switch if applicable.
Check for correct battery for
the adapter and adapter
contacts. Clean all contacts.
Run Boost, (see Boost,
page 38).
NO NEGATIVE
SLOPE ON
TIMEOUT
1
125
A plateau was detected
when the battery voltage
was low. I.e. The battery
acted as if it was fully
charged even though it isn’t.
Increase the charge rate in
the C-code. If the battery was
in storage, use Ext. Prime. If
all fails, discard the battery.
NULL C-CODE IN
ADAPTER
211
An empty C-code is
selected.
Select a programmed C-code
or program the selected
empty C-code.
OVER VOLTAGE 120
Battery voltage is too high. Verify the C-code voltage
setting, (see Battery Voltage
(Volts), page 49).
If the battery is new, charge it
for a few minutes in the
original charger.
Li-ion and Li-Ph safety circuits
may be activated. Discharge
the battery in its original
equipment for a few minutes.
For SLA batteries, check the
electrolyte.
If all fails, discard the battery.
Cadex Electronics Inc. C7000-C Series Battery Analyzers .
140

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cadex C7400 and is the answer not in the manual?

Cadex C7400 Specifications

General IconGeneral
BrandCadex
ModelC7400
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals