Service Mode > FUNCTION GR.
Service Mode > FUNCTION GR. > MEAP
CLEAR CDS Deletion of all including APL_CDS
Detail To delete all data including APL_CDS at the next startup.
Adj/Set/Operate Method
Select the item, and then press OK key.
Supplement/Memo
MEAP installed model only
CLEAR MEAP Deletion of MEAP application data
Detail To delete the following data, retained by MEAP application, at the next startup.
- MEAP application
- Data retained by MEAP application
- Data retained in the service-purpose area of MEAP platform
Adj/Set/Operate Method
Select the item, and then press OK key.
Supplement/Memo
MEAP installed model only
UFOS-DSP Dspl/hide uniFLOW Online Setup icon
Detail To set whether to display or hide the uniFLOW Online Setup icon
Display/Adj/Set Range
Off/On
Off: Hide
On: Display
Default Value
Off
Supplement/Memo
MEAP installed model only
Check File System File system check
Detail To determine whether the file system including APL_KEEP is normal.
Use Case
When a trouble such as the disappearance of app license occurs
Adj/Set/Operate Method
Select the setting value, and then press OK key.
Supplement/Memo
MEAP installed model only
Communication Test CDS communication test
Detail To execute Content Delivery System communication test.
Adj/Set/Operate Method
Select the item, and then press OK key.
Supplement/Memo
MEAP installed model only
FSCloseMode For R&D use
LCDSFLG Permission setting for user administrator to use CDS in local environment (L-CDS)
Detail To set whether to allow the user administrator to use the CDS in local environment (L-CDS).
Adj/Set/Operate Method
Select the item, and then press OK key.
Display/Adj/Set Range
Off/On
Default Value
Off
Supplement/Memo
MEAP installed model only
MEAP FUNCTION MEAP recovery
Detail To recover MEAP.
Adj/Set/Operate Method
Select the item, and then press OK key.
Display/Adj/Set Range
Off/On
Default Value
On
Supplement/Memo
MEAP installed model only
MEAP-PN Specification of MEAP HTTP port number
Detail To specify the port number of MEAP HTTP.
Adj/Set/Operate Method
Select the item, and then press OK key.
Display/Adj/Set Range
0 to 65535
Default Value
8000
Supplement/Memo
MEAP installed model only
9. Service Mode