EasyManua.ls Logo

Canon PC920 - Timing Chart for the Image Formation System

Canon PC920
393 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4 IMAGE FORMATION SYSTEM
COPYRIGHT
©
1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-3
Figure 4-102
,
Copy Start key
ON
STBY
INTR
SCFW
forward
SCFWSCRV
Reverse
-625V
3200V
-400V
0.5sec.(approx.)
LSTR
STBY
Main motor (M1)
Scanning lamp (LA1)
Primary AC bias
Transfer bias
Transfer cleaning bias
Transfer reference
bias (ATVC)
Static eliminator bias
Pre-registration roller
paper sensor (Q751)
Primary DC bias
Developing AC bias
Developing DC bias
Scanner
SCRV
-500V
0.6sec.(approx.)
0.6sec.(approx.)
B. Timing Chart for the Image Formation System
Basic Sequence of Operations (Direct, 2 copies, continuous)