7–39 62-11640
00074 PHASE REVERSED
• ACTIVATION: If the system is in electric mode and the Stop/Run Switch is ON and the system cannot
properly detect the phase.
• UNIT CONTROL: Engine Operation: Alarm only.
Electric Operation: Required Shutdown.
• RESET CONDITION: Auto reset when and the phase reversed switch = phase reverse okay for 2 sec-
onds, or switch to diesel mode. Alarm may be manually reset using the display mounted keys or by turn-
ing the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active
alarm should clear itself (see reset condition above). Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1. Check Circuit Breaker On The Main External Power Supply
a. Check the 30A supply circuit breaker to make sure it is on.
b. Check the voltage in the plug. 460V / 3 / 60Hz.
2. Check For Power In The Control Box, PSCON or PSCON2
a. Check PSCON and PSCON2. Use Component Test Mode (Section 5.2.4) to test. Refer to Sec-
tion 2.11 for amp values. View current draw in Component Test Mode screen.
b. Check for voltage at PSCON L1-L2, L2-L3, L1-L3. All three readings must be 460V + 10%.
c. Check for voltage at PSCON2 L1-L2, L2-L3, L1-L3. All three readings must be 460V + 10%.
3. Check PSCON, and PSCON2
Use Component Test Mode (Section 5.2.4) to test. Refer to Section 2.11 for amp values. View cur-
rent draw in Component Test Mode screen.
4. Check Current Transformer (CT)
a. Check current value. Power up control system in PC Mode. (Refer to Section 5.3.2.) Check Unit
Data. Must be -2.0 to 1.5A with no load.
b. Check CT power from main microprocessor. +5 VDC from terminal 2MM-29 to PCM-31
c. Check CT ground to main microprocessor. Check wiring from terminal 2MM-23 to PCM-30
d. Check CT signal to main microprocessor. Check wiring from terminal 2MM-12 to PCM-29

Table of Contents

Other manuals for Carrier TRANSICOLD Vector 8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD Vector 8500 and is the answer not in the manual?

Carrier TRANSICOLD Vector 8500 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVector 8500
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals