7–117 62-11640
26102 WATER TEMP LOW ENCU
• ACTIVATION: Voltage of water temperature sensor is 0.1 V or less
• UNIT CONTROL: Engine Operation: Alarm only.
Electric Operation: Will not activate in electric operation.
• RESET CONDITION: If trigger on message not received for 5 seconds, alarm reset or alarm may be
manually reset by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in Notes Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1. Refer to:
00129 CHECK ENG COOLANT SENSOR
P00155 CHECK COOLANT TEMP SENSOR.
26103 WATER TEMP HIGH ENCU
• ACTIVATION: Voltage of water temperature sensor is 4.9 V or above
• UNIT CONTROL: Engine Operation: Alarm only. Electric Operation: Will not activate in electric operation.
• RESET CONDITION: If trigger on message not received for 5 seconds, alarm reset or alarm may be
manually reset by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in Notes Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1. Refer to:
00129 CHECK ENG COOLANT SENSOR
P00155 CHECK COOLANT TEMP SENSOR.
26104 BATTERY VOLTAGE HIGH ENCU
• ACTIVATION: ECU recognition of battery voltage is above 18 V.
• UNIT CONTROL: Engine Operation: Required Shutdown.
Electric Operation: Will not activate in electric operation.
• RESET CONDITION: If trigger on message not received for 5 seconds, alarm reset or alarm may be
manually reset by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in Notes Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1. Refer to 00015 BATTERY VOLTAGE TOO HIGH.

Table of Contents

Other manuals for Carrier TRANSICOLD Vector 8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD Vector 8500 and is the answer not in the manual?

Carrier TRANSICOLD Vector 8500 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVector 8500
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals