3–13 62-11640
3.9 CONTINUOUS OPERATION
1. With the system powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode press
the START-STOP/CONTINUOUS key until “CONTINUOUS” is displayed & highlighted.
2. The message “CONTINUOUS RUN MODE SELECTED” will be displayed in the MessageCenter for 10 sec-
onds.
3. The operation indication in the status bar will no longer be highlighted. The unit is now in Continuous Operation.
In Continuous Operation, the unit will not shutdown
except in response to a shutdown alarm. Refer to Sec-
tion 4.6 for more detailed information on Continuous
Operation.
The control system may be configured with continuous
operation tied to setpoint ranges for either frozen or
perishable loads. The START-STOP/CONTINUOUS
key is locked out if “CONTINUOUS LOCKED” displays
in the MessageCenter when the key is pressed and the
unit is in Continuous Operation or “START-STOP
LOCKED” displays in the MessageCenter when the
key is pressed and the unit is in Start-Stop Operation.
Refer to Section 5.2.3 for more information on Config-
urations.
If the unit fails to start after three start attempts the
A00031 - “FAILED TO START-AUTO” alarm will be
activated. While running, if the unit shuts down, an
internal counter keeps track of the shutdowns. Should
the unit shutdown three consecutive times without run-
ning a minimum of 15 minutes between shutdowns the
A00030 - “FAILED TO RUN MINIMUM TIME” alarm will
be activated. The shutdown counter is cleared when
the unit has run for 15 minutes.
CONTINUOUS
START/STOP
MENU
ALARM
COOLDIESELSTART/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
IntelliSets (2 of 7)
BACK EXIT
IntelliSet Off
Banana Active
Flowers
Lettuce
Cheese
PRETRIP MENU
BACK EXIT
Start Pretrip
View Results of Last Pretrip
COOLDIESELSTART/STOP
STATUS OK
36
36
.2
BOX TEMPERATURE F SETPOINT F
COOL
DIESEL
CONTINUOUS RUN MODE SELECTED
36
36
.2
BOX TEMPERATURE F SETPOINT F
CONTINUOUS
1 & 3
1
2

Table of Contents

Other manuals for Carrier TRANSICOLD Vector 8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD Vector 8500 and is the answer not in the manual?

Carrier TRANSICOLD Vector 8500 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVector 8500
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals