62-11640 3–12
3.8 START-STOP OPERATION
1. With the system powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode, press
the START-STOP/CONTINUOUS key until “START/STOP” is highlighted.
2. The message “START/STOP MODE SELECTED” will be displayed in the MessageCenter for 10 seconds.
3. The operation indication in the status bar will no longer be highlighted. The unit is now in Start-Stop Operation.
Start-Stop is provided to reduce fuel or power con-
sumption. This feature allows full automatic control of
unit shut down and restart by monitoring refrigerated
compartment temperature, battery charge condition
and engine coolant temperature (Engine Operation
only).
NOTE
In Electric Operation, if battery condition is
the only reason the unit needs to operate,
the compressor will stop but the battery
charger will remain energized.
The main function of Start-Stop Operation is to turn off
the unit near setpoint to provide an efficient tempera-
ture control system and to initiate a restart sequence
after certain conditions are met.
The control system may be configured with Start-Stop
operation tied to setpoint ranges for either frozen or
perishable loads.
The Start-Stop/Continuous key is locked out if “START-
STOP LOCKED” displays in the MessageCenter when
the key is pressed and the unit is in Start-Stop Opera-
tion or “CONTINUOUS LOCKED” displays in the Mes-
sageCenter when the key is pressed and the unit is in
Continuous Run Operation. Refer to Section 5.2.3 for
Configuration information.
If the unit fails to start after three start attempts the A
00031 - “FAILED TO START-AUTO” alarm will be acti-
vated. While running, if the unit shuts down, an internal
counter keeps track of the shutdowns. Should the unit
shutdown three consecutive times without running a
minimum of 15 minutes between shutdowns the
A00030 - “FAILED TO RUN MINIMUM TIME” alarm will
be activated. The shutdown counter is cleared when
the unit has run for 15 minutes.
Refer to Section 4.5 for more detailed information on
Start-Stop Operation.
CONTINUOUS
START/STOP
MENU
ALARM
COOLDIESELSTART/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
IntelliSets (2 of 7)
BACK EXIT
IntelliSet Off
Banana Active
Flowers
Lettuce
Cheese
PRETRIP MENU
BACK EXIT
Start Pretrip
View Results of Last Pretrip
COOL
DIESEL
START/STOP MODE SELECTED
36
36
.2
BOX TEMPERATURE F SETPOINT F
START/STOP
1 & 3
1
2

Table of Contents

Other manuals for Carrier TRANSICOLD Vector 8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD Vector 8500 and is the answer not in the manual?

Carrier TRANSICOLD Vector 8500 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVector 8500
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals