58
Advanced function Description
ROBOT BURN BACK
WATER COOLER OPTIONAL
ROBOT CONN. MODE RI-A 1
ROBOT REG. MODE ABS. WIRE SP.
ROBOT VOLTAGE ENABLED
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
NOT ACTIVE - In this mode, regulation of the BURN BACK is active, via the welding
machine’s panel.
ACTIVE - In this mode, regulation of the BURN BACK is active, via the robot interface
board.
ROBOT DYNAMICS
WATER COOLER OPTIONAL
ROBOT CONN. MODE RI-A 1
ROBOT REG. MODE ABS. WIRE SP.
ROBOT VOLTAGE ENABLED
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
NOT ACTIVE - In this mode, DYNAMIC regulation is active, via the welding machine’s
panel.
ACTIVE - In this mode, DYNAMIC regulation is active, via the robot interface board.
ROBOT PULSE FREQ. (ROBOT PULSE
FREQUENCY)
WATER COOLER OPTIONAL
ROBOT CONN. MODE RI-A 1
ROBOT REG. MODE ABS. WIRE SP.
ROBOT VOLTAGE ENABLED
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
NOT ACTIVE - In this mode, PULSATION FREQUENCY regulation is active, via the
welding machine’s panel.
ACTIVE - In this mode, PULSATION FREQUENCY regulation is active, via the robot
interface board.
GAS FLUX CONTROL
WATER COOLER OPTIONAL
ROBOT CONN. MODE RI-A 1
ROBOT REG. MODE ABS. WIRE SP.
ROBOT VOLTAGE ENABLED
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
NOT ACTIVE - In this mode the GAS FLOW input for the MCB-3 motor control box is
ignored.
ACTIVE - In this mode the GAS FLOW input for the MCB-3 motor control box is checked,
and if necessary the relevant alarm is activated.
WATER FLUX CONTROL
WATER COOLER OPTIONAL
ROBOT REG. MODE ABS. WIRE SP.
ROBOT VOLTAGE ENABLED
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
WATER FLUX CONTROL DISABLED
NOT ACTIVE - In this mode the WATER FLOW input for the MCB-3 motor control box is
ignored.
ACTIVE - In this mode the WATER FLOW input for the MCB-3 motor control box is
tested, and if necessary the relevant WATER FAULT alarm is activated via the output of
the box.
WIRE PRESENCE CONTROL
WATER COOLER OPTIONAL
ROBOT VOLTAGE ENABLED
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
WATER FLUX CONTROL DISABLED
WIRE PRESENCE CONTROL DISABLED
NOT ACTIVE - In this mode the WIRE PRESENCE input for the MCB-3 motor control
box is ignored.
ACTIVE - In this mode the WIRE PRESENCE input for the MCB-3 motor control box is
tested, and if necessary the relevant WIRE MISSING alarm is activated via the robot
interface board.
CURRENT MISSING MASK
WATER COOLER OPTIONAL
ROBOT ELECTRONIC INDUCTANCE DISABLED
ROBOT BURN BACK DISABLED
ROBOT DYNAMICS DISABLED
ROBOT PULSE FREQ. DISABLED
GAS FLUX CONTROL DISABLED
WATER FLUX CONTROL DISABLED
WIRE PRESENCE CONTROL DISABLED
CURRENT MISSING MASK 300 ms
XXX [ms] - During and on completion of welding, this indicates the time lapse between
current zeroing and deactivation of the CURRENT SENSE digital output on the robot
interface board.