1 Operational Manual
a) Check limit switch of minimum thickness. (Input 04).
b) If the actual thickness of mold exceeds the minimum capacity of the machine, please
change to a smaller machine.
3.14 “022 Mold Adjustment Exceeds the Maximum Size”
(A) The backward stroke of mold adjustment exceeds the limit switch of maximum mold
thickness. (Input 05 ON)
(B) Remedy:
a) Check limit switch of maximum thickness. (Input 05)
b) If the actual thickness of mold exceeds the maximum capacity of the machine, please
change to a larger machine.
3.15 “Mold Adjustment Counter Error” “
(A) The message will appear if the input impulse signal of mold adjustment counter is
incorrect when the mold adjustment motor is running.
(B) Remedy:
a) Check whether the limit switch (Input 31) of mold-adjustment counter is incorrect
when the mold-adjustment motor is running.
b) Measure the current when the mold-adjustment is opening. If the current exceeds
normal range, please check the mold-adjustment mechanism or the motor.
c) Check whether the setting range of timer (Tim 38) is normal. The time set by Tim
38 can not be changed at will or too long, otherwise the mold-adjustment mechanism
will be damaged.
3.16 “027 Turn off the Power to Restart”
(A) If the automatic shut down function in menu 32 is set to “stop heater” or “stop
oil pump and heater”; the heater will be turned off when abnormal condition occurs in machine
operation. If in manual operation, the injection operation can not be done when the message
appears.
(B) Remedy: Turn off the power then turn it back on.