1 Operational Manual
(B) Remedy: release mold-close key.
3.34 “051 The Opening Mold Has Stopped” “
(A) When press mold-open key, at the end of mold-opening, this message
will come out.
(B) Remedy: release mold-open
key.
3.35 “052 The Opening Mold Has Not Yet Stopped”
When press ejector forward or mold adjustment key while mold was not at its end
position, this message will come out. Press mold-opening key until the end of mold
position.
3.36 “053 The Distance of Ejector Has Stopped”
When press ejector forward key, and ejector has reached the setting
position, this message will come out.
Remedy: Release ejector forward key.
3.37 “054 The Backward Distance of Ejector Has Stopped” “
When press ejector backward key, and ejector has reached the setting
position, this message will come out.
Remedy: Release ejector backward key.
3.38 “055 The Distance of Plasticizing Has Stopped”
When press plasticizing key, and plasticization has reached the setting
position, this message will come out. Remedy: release plasticizing key.