1 Operational Manual
05/02/03
179
3.43 “060 The Plasticizing Volume is Not Enough or Too Much”
(A) Injection final position is over injection leakage position
1111.1
at auto mode.
(B) Remedy:
a)
Check nozzle and mold injecting entrance, also the center arch of stationary
board.
b)
Check the injection leakage position
1111.1
, it must be smaller than
uuuu.u
.
3.44 “061 Not Normal Checking for Safe Door”
(A) If both front and back safety doors are not closed warning message will show.
(B) Remedy:
a)
Check both front and back safety doors
switch.
b) Fix front safety door and back doors aid (input02) make sure is functioning properly.
3.45 065 The Hopper is empty or clogged”
(A) Plasticizing and decompression did not complete its stroke in cooling time setting
at auto mode.
(B) Remedy:
a)
Check whether there is still material in hopper or hopper is clogged.
b)
Please check whether the plasticizing parameter is too low or the cooling time
is set too short.
c)
Please check whether the temperature of barrel is too low.
3.46 “066 The Products Are Reached the Setting”
(A) In menu (43) the number of good parts
LLLLLLLL
, in auto production, if number
of good products have has reach the setting value, alarm will sound.
(B) Remedy:
a) If the production batch counting
NNNNNNNN
is not set, press key to cancel
the message and reset the good part counting.
b) If the production batch counting
NNNNNNNN
is set, the message will disappear
from the next cycle, the good part counting reset to zero automatically, batch
counting increase one.