1 Operational Manual
3.41 “058 The Safe Cover of Nozzle Has Not Yet Closed”
(A) Nozzle protection guard was opened, alarm message will show.
(B) Remedy: close nozzle protection guard.
3.42 “059 The Nozzle is clogged
(A) Injection position did not reach the injection choke position
mmmm.m
in injection
time
zzzz.z
at auto mode.
(B) Remedy:
a) Check if nozzle is blocked. If yes, please clean up the nozzle.
b) Please check whether there is any foreign substance in mold. If yes, please
remove foreign substance.
c) Go to menu (11) to modify parameter, injecting time
zzzz.z
and place where stuck
mmmm.m
adjust to proper value.
INJECTION SETTING ????.?mm
CUSHION END : uuuu.umm FILLING TIME : xx.xxSEC FEEDING TIME : wwww.wSEC
Tt.ff Tt.ee Tt.dd Tt.cc Tt.bb Tt.aa
TIME OD STAGE
6 5 4 3 2 1 DOSING END
UU QQ MM II EE AA SPEED %
VV RR NN JJ FF BB PRESSURE%
zzz.z TIME SEC
WWW.W SSS.S OOO.O KKK.K GGG.G CCC.C ZZZ.Z POSITION
XX TT PP LL HH DD 100% PERSENT%
3 2 1
gg dd aa SPEED %
hh ee bb PRSSSURE %
iii.i fff.f ccc.c TIME SEC
pp.p oo.o nn.n SLOPE %
HOLDING PRESSURE AT :
jjjbar BOOST INJECTION:
INJECT LEAKAGE POSTION:
llll.lmm INJECTION CHOCKED POSTION: mmmm.mmm
INJECTION MODE:
nnnnnnnnnnnnnn
SET
Menu11
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
04/08/13
178

Table of Contents