EasyManua.ls Logo

Chen Hsong CDC-2000 - Page 189

Default Icon
208 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 Operational Manual
05/02/03
183
LUBRICATION SETTING
TOGGLE SYSTEM LUBRICATION AT EVERY
GGGGG CYCLES
NEXT LUBRICATION AT KKKKK CYCLE LATER
LUBRICATIN TIME
HHHH.H SEC
LUBRICATIN MONITORING TIME
IIII.I SEC
GREASE LUBRICATION AT EVERY
JJJJJ CYCLES (BY MANUAL)
NEXT LUBRICATION AT LLLLL CYCLE LATER
GREASE LUBRICATION ATALARM RESET
RESET
Menu10
F1 F2 F3
F4 F5
F6
F7
F8
F9 F10
3.50 “072 Clean the Mold”
(A)When mold closing to low-pressure stroke, and if the low-pressure stroke can not
turn into high-pressure within the low-pressure warning time(Tim 07)
(B)Remedy:
a)
Please check whether there is product or unknown substance in the mold. If yes,
clean up the mold.
b)
Check/modify low pressure warning time
VVV.V
in menu 03.
c)
Check low-pressure clamping speed
DD
, press
EE
and position
FFFFF
setting
in menu 03.

Table of Contents

Related product manuals