1 Operational Manual
05/02/03
187
a)
Check/replace second section thermocouple.
b)
Check/replace second section MC and heater.
3.55 “092 Temperature Sensor Breakdown at Sector 3”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy:
a)
Check/replace third section thermocouple.
b)
Check/replace third section MC and heater.
3.56 “093 Temperature Sensor Breakdown at Sector 4”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy:
a)
Check/replace forth section thermocouple.
b)
Check/replace forth section MC and heater.
3.57 “094 Temperature Sensor Breakdown at Sector 5”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy:
a)
Check/replace fifth section thermocouple.
b)
Check/replace fifth section MC and heater.
3.58 “095 Temperature Sensor Breakdown at Sector 6”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy:
a)
Check/replace sixth section thermocouple.
b)
Check/replace spare MC and heater.
3.59 “096 TC Temperature Sensor Breakdown for Backup”
(A)Thermal couple failure or the temperature did not rise to 60 degree C within 20
minutes.
(B)Remedy:
a)
Check/replace spare thermocouple.
b)
Check/replace spare MC and heater.