(B)Remedy:
a)
Check/replace MC and heater.
b)
Modify T2 deviation settings in menu 20.
3.63 “ 102 The Practical Temperature Is Too Low at Sector 3 “
(A)Intending to do injection/plasticizing/decompression while temperature difference
between the actual values and the settings greater than T3 low deviation setting,
alarm will sound.
(B)Remedy:
a)
Check/replace MC and heater.
b)
Modify T3 deviation settings in menu 20.
3.64 “ 103 The Practical Temperature Is Too Low at Sector 4 “
(A)Intending to do injection/plasticizing/decompression while temperature difference
between the actual values and the settings greater than T4 low deviation setting,
alarm will sound.
(B)Remedy:
a)
Check/replace MC and heater.
b)
Modify T4 deviation settings in menu 20.
3.65 “ 104 The Practical Temperature Is Too Low at Sector 5 “
(A)Intending to do injection/plasticizing/decompression while temperature difference
between the actual values and the settings greater than T3 low deviation setting,
alarm will sound.
(B)Remedy:
a)
Check/replace MC and heater.
b)
Modify T5 deviation settings in menu 20.
3.66 “ 105 The Practical Temperature Is Too Low at Sector 6 “
(A)Intending to do injection/plasticizing/decompression while temperature difference
between the actual values and the settings greater than T6 low deviation setting,
alarm will sound.
(B)Remedy:
a)
Check/replace MC and heater.
b)
Modify T6 deviation settings in menu 20.
3.67 “ 106 The Practical Temperature Is Too Low for Backup “
(A)Intending to do injection/plasticizing/decompression while temperature difference
between the actual values and the settings greater than TC low deviation setting,