1 Operational Manual
to make a pick among three modes, and push to complete the selection. Code
description are shown below:
A) Heater off or in timer mode.
B) Heating: Function selection for barrel normal control.
C) Stand-by temperature mode: (Exclusive of nozzle)
For instance,“YY” in set at 20% , 250
as the set temperature
250
×
20%= 50
℃。
250
- 50
=200
℃。
The set temperature lowered to 200
stays under control.
2.21.6 YY: Under stand-by temperature mode, the set value for lowered temperature.
2.21.7 CDC-2000 Material temperature can be memorized 20 groups as follows:
A) Set method:
A.a) Move cursor to
material
to set parameter, and press
to complete a
correction.
A.b) Push
to move cursor to T1~T6, then set the temperature and push
to complete a correction.
B) Fast setting method:
Move cursor to “Material”, push
or
to select the adequate
material, then push
and so T1~T6 and TC can be replaced by memorial
setting value.