Multi-Channel Sync Hipot Tester 19020/19020-4/19021/19021-4/19022/19022-4
User’s Manual
Example: Input the command SAF:CHAN005:RES:ALL:TIME?
The tester returns 3.000000E+00, 3.000000E+00, 1.000000E+00,
2.500000E+00, 2.500000E+00, 1.000000E+00, 1.000000E+00,
0.500000E+00, 3.000000E+00, 1.000000E+00.
Description: The returned string is the time required for testing for CH5
STEP1~STEP10 of Address 0 host, that is 3.0sec, 3.0sec, 1.0sec,
2.5sec,2.5sec, 1.0sec, 1.0sec, 0.5sec, 3.0sec, 1.0sec.
[:SOURce]:SAFety[:CHANnel]<m>:RESult:AREPort < boolean > | ON | OFF
It sets if reporting the test result automatically (only valid for RS232 interface.) This
command is only valid for this Tester, so the Address 0 host <m> can use 001, Address
1 host <m> can use 101 and so forth. The Address 9 host <m> can use 901. The
returned data is Total Pass/Fail state and its format is string in “PASS” or “FAIL”.
Example: Input the command SAF001:RES:AREP ON
Description: It means to set the Address 0 host to return the test result
automatically after the test is done. If the test result of all channels of
Address 0 host is PASS, it returns “PASS” or “FAIL” will be returned.
[:SOURce]:SAFety[:CHANnel]<m>:RESult:AREPort?
It queries the device if reporting the test result automatically. The return is 1 or 0.
(Applicable for RS232 interface only.)
Example: Input the command SAF001:RES:AREP?
The tester returns 1.
Description: The returned 1 means Address 0 host will report the test result
automatically once the test is done.
[:SOURce]:SAFety[:CHANnel]<m>:RESult:COMPleted?
It queries the device if all settings are executed completely. The return is 1 or 0.
Example: Input the command SAF001:RES:COMP?
The tester returns 1.
Description: The returned 1 means Address 0 host has completed the execution of
all settings.
[:SOURce]:SAFety[:CHANnel]<m>:RESult:STEP<n>[:JUDGment]?
It queries the judgment of specified STEP when the Screen sets to On. The format of
variable <m> at the end of [:CHANnel] is 3 digits. The first digit is Frame index in the
range of 0~9 and the last two digits are Channel index in the range of 01~10 (19020/
19021/19022) or 01~04(19020-4/19021-4/19022-4). When the variable is ignored it is
001 to indicate Channel 1 of the Master. Return format: First Step Result, Second Step
Result, ..., Last Step Result. The table below lists the definition of Code:
Code of Test Result