Table 126: Modbus memory map: Status of transistor digital outputs (Table 3)�
Transistor digital outputs: Slot2
Configuration variable
Address
Alarm
Impulse
output
Output
1
Output
2
Output
3
Output
4
Output
5
Output
6
Output
7
Output
8
Latch kWh o Wh CA58 CA6C CA80 CA94 CAA8 CABC CAD0 CAE4
Delay in the
Connection
Wh o mWh CA5A CA6E CA82 CA96 CAAA CABE CAD2 CAE6
Delay in the
Disconnection
Factor
Energy meter
CA5B CA6F CA83 CA97 CAAB CABF CAD3 CAE7
Alarm activation
date: Year
- CA5C CA70 CA84 CA98 CAAC CAC0 CAD4 CAE8
Alarm activation
date: Month
- CA5D CA71 CA85 CA99 CAAD CAC1 CAD5 CAE9
Alarm activation
date: Day
- CA5E CA72 CA86 CA9A CAAE CAC2 CAD6 CAEA
Alarm activation
time: Hour
- CA5F CA73 CA87 CA9B CAAF CAC3 CAD7 CAEB
Alarm activation
time: Minutes
- CA60 CA74 CA88 CA9C CAB0 CAC4 CAD8 CAEC
Alarm activation
time: Seconds
- CA61 CA75 CA89 CA9D CAB1 CAC5 CAD9 CAED
Not used CA62 CA76 CA8A CA9E CAB2 CAC6 CADA CAEE
Not used CA63 CA77 CA8B CA9F CAB3 CAC7 CADB CAEF
Status CA64 CA78 CA8C CAA0 CAB4 CAC8 CADC CAF0
Alarm Status CA65 CA79 CA8D CAA1 CAB5 CAC9 CADD CAF1
Note: The 14 registers must be read at once (as a group), otherwise it will respond with an
error.
Table 127: Modbus memory map: Status of transistor digital outputs (Table 4)�
Transistor digital outputs: Slot3
Configuration variable
Address
Alarm
Impulse
output
Output
1
Output
2
Output
3
Output
4
Output
5
Output
6
Output
7
Output
8
Latch kWh o Wh CE40 CE54 CE68 CE7C CE90 CEA4 CEB8 CECC
Delay in the
Connection
Wh o mWh CE42 CE56 CE6A CE7E CE92 CEA6 CEBA CECE
Delay in the
Disconnection
Factor
Energy meter
CE43 CE57 CE6B CE7F CE93 CEA7 CEBB CECF
Alarm activation
date: Year
- CE44 CE58 CE6C CE80 CE94 CEA8 CEBC CED0
Alarm activation
date: Month
- CE45 CE59 CE6D CE81 CE95 CEA9 CEBD CED1
Alarm activation
date: Day
- CE46 CE5A CE6E CE82 CE96 CEAA CEBE CED2
Alarm activation
time: Hour
- CE47 CE5B CE6F CE83 CE97 CEAB CEBF CED3
Alarm activation
time: Minutes
- CE48 CE5C CE70 CE84 CE98 CEAC CEC0 CED4
Alarm activation
time: Seconds
- CE49 CE5D CE71 CE85 CE99 CEAD CEC1 CED5
Not used CE4A CE5E CE72 CE86 CE9A CEAE CEC2 CED6
291
Instruction Manual
CVM-A1000 - CVM-A1500

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Circutor CVM-A1500 and is the answer not in the manual?

Circutor CVM-A1500 Specifications

General IconGeneral
BrandCircutor
ModelCVM-A1500
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals