1-10
Cisco ONS SONET TL1 Command Guide, R6.0
Chapter 1 General Information
1.8 Default Values
1.8 Default Values
1.8.1 BLSR
1.8.2 Cross-Connections
1.8.3 Environment Alarms and Controls
Table 1-5 BLSR Default Values
BLSR Default
RVRTV Y
RVTM 5.0 minutes
SRVRTV Y
SRVTM 5.0 minutes
Table 1-6 Cross-Connections Default Values
Cross-Connections Default
CCT 2WAY for both STSp and VT1 cross-connections
Table 1-7 Environment Alarms and Controls Default Values
Environment Alarms and
Controls Default
OPR-EXT-CONT CONTTYPE is set as one provisioned in the respective AID, there is not
default for it. It is only used as a filter if entered. DUR is always taken as
CONT.
RTRV-ATTR-CONT There is no default for CONTTYPE. It is only used as a filter if entered.
RTRV-ATTR-ENV There is no default for both NTFCNCDE and ALMTYPE, which are only
used as filters if entered.
RTRV-EXT-CONT CONTTYPE defaults to the conttype associated with the AID.
SET-ATTR-ENV NTFCNCDE defaults to NR. ALMTYPE defaults to NULL. ALMMSG
defaults to \“Env Alarm Input 1\”.