Chapter 16: Viewing Statistics
Managing RMON Statistics
SGE2000/SGE2000P Gigabit Ethernet Switch Reference Guide
Chapter
16
Rising Event — Selects an event which is defined in the Events table that triggers the rising
threshold alarm. The Events Table is displayed in the RMON Events page.
Falling Threshold — Displays the falling counter value that triggers the falling threshold alarm.
The falling threshold is graphically presented on top of the graph bars. Each monitored variable is
designated a color.
Falling Event — Selects an event which is defined in the Events table that triggers the falling
threshold alarm. The Events Table is displayed in the RMON Events page.
Startup Alarm — Displays the trigger that activates the alarm generation. Rising is defined by
crossing the threshold from a low-value threshold to a higher-value threshold.
Interval — Defines the alarm interval time in seconds.
Owner — Displays the device or user that defined the alarm.
2. Click the Add button. The Add RMON Alarm Page opens:
Add RMON Alarm Page
The Add RMON Alarm Page contains the following fields:
Alarm Entry — Indicates a specific alarm.
Interface — Displays the interface for which RMON statistics are displayed. The possible field v
values are:
Port — Displays the RMON statistics for the selected port.
LAG — Displays the RMON statistics for the selected LAG.
Counter Name — Displays the selected MIB variable.

Table of Contents

Other manuals for Cisco SGE2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 and is the answer not in the manual?

Cisco SGE2000 Specifications

General IconGeneral
Jumbo Frame Support9KB
VLANsUp to 256
ManagementWeb-based, SNMP, CLI
StandardsIEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 802.1D, 802.1Q, 802.1p, 802.1w
Dimensions440 x 44 x 257 mm
Power Supply100 to 240V AC, 50-60 Hz
Operating Temperature0°C to 40°C
Storage Temperature-20 to 70°C (-4 to 158°F)
Humidity10% to 90% non-condensing
Weight3.2 kg