Connect all power cords to a properly wired and grounded electrical outlet.
Connect to properly wired outlets any equipment that will be attached to this product.
When possible, use one hand only to connect or disconnect signal cables.
Never turn on any equipment when there is evidence of fire, water, or structural damage.
Disconnect the attached power cords, telecommunications systems, networks, and modems
before you open the device covers, unless instructed otherwise in the installation and configu-
ration procedures.
Connect and disconnect cables as described in the following table when installing, moving, or
opening covers on this product or attached devices.
Connect cables
Turn OFF all power sources and equipment to be attached to this product.
Attach all cables to the devices.
Attach signal cables to the connectors.
Attach power cords to power sources. For DC systems, ensure correct polarity of -48 VDC con-
nections: RTN is (+) and -48 VDC is (-). Earth ground should use a two-hole lug for safety.
Turn ON all the power sources.
Disconnect cables
Turn OFF all power sources and equipment to be attached to this product.
For AC systems, remove all power cords from the shelf power receptacles or interrupt power at
the ac power distribution unit.
For DC systems, disconnect DC power sources at the breaker panel or by turning o the power
source, then remove the DC cables.
Remove the signal cables from the connectors.
Remove all cables from the devices
Statement 2:
Caution: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are
installed, note the following:
Do not remove the covers. Removing the covers of the laser product might result in exposure to
hazardous laser radiation. There are no serviceable parts inside the device.
Use of controls or adjustments or performance of procedures other than those specified herein
might result in hazardous radiation exposure.
Danger: Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the follow-
ing:
© 1999-2019 Citrix Systems, Inc. All rights reserved. 106

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX Series and is the answer not in the manual?

Citrix ADC MPX Series Specifications

General IconGeneral
TypeApplication Delivery Controller
MemoryUp to 256 GB
Power SupplyRedundant
Product SeriesMPX
Ports10/25/40/100 Gbps Ethernet
Operating SystemCitrix ADC
ManagementCitrix ADM
Form FactorRack-mountable