Citrix ADC MPX
Use the BIOS POST code to detect errors
February 11, 2019
You can read the BIOS POST code by using the LOM GUI or the shell. To interpret the BIOS Beep codes,
see https://www.ami.com/support/doc/AMI_Aptio_4.x_Status_Codes_PUB.pdf.
Read the BIOS post code by using the LOM GUI
Navigate to Miscellaneous > BIOS Post Snooping.
Read the BIOS post code by using the shell
At the prompt, type:
ipmitool raw 0x30 0x2a
Upgrade the LOM firmware on a Citrix ADC MPX appliance
November 14, 2019
Citrix has automated the upgrade of LOM firmware within Citrix ADC MPX soware. It is no longer
necessary to know your hardware platform or download any LOM firmware.
Note: This procedure requires two reboots to complete and therefore a disruption in production traf-
fic is expected. Citrix recommends that you perform the upgrade during a maintenance window. In
a high availability setup, perform the upgrade on the secondary node to minimize disruption to pro-
duction traic.
Upgrade a standalone appliance
Perform the following steps:
1. Download and install the latest Citrix ADC soware build.
2. Reboot the appliance to install the new drivers that are needed for the LOM upgrade.
3. At the command line, type: shell.
4. At the shell prompt, type: upgrade_bmc.sh
© 1999-2019 Citrix Systems, Inc. All rights reserved. 153