11 MAC Address : 00:25:90:3f:5e:d0
12 SNMP Community String : public
13 IP Header : TTL=0x00 Flags=0x00 Precedence=0x00 TOS=0x00
14 BMC ARP Control : ARP Responses Enabled, Gratuitous ARP
Disabled
15 Gratituous ARP Intrvl : 0.0 seconds
16 Default Gateway IP : 0.0.0.0
17 Default Gateway MAC : 00:00:00:00:00:00
18 Backup Gateway IP : 0.0.0.0
19 Backup Gateway MAC : 00:00:00:00:00:00
20 802.1q VLAN ID : Disabled
21 802.1q VLAN Priority : 0
22 RMCP+ Cipher Suites : 1,2,3,6,7,8,11,12,0
23 Cipher Suite Priv Max : aaaaXXaaaXXaaXX
24 : X=Cipher Suite Unused
25 : c=CALLBACK
26 : u=USER
27 : o=OPERATOR
28 : a=ADMIN
29 : O=OEM
Perform power control operations by using the LOM port
February 11, 2019
Through the LOM port, you can remotely perform power control operations, such as graceful shut-
down and restart, power cycling the appliance, and restarting the BMC microcontroller. A cold restart
takes longer than a warm restart. In a cold restart, you switch o power to the appliance and then
switch it back on.
Perform power control operations by using the GUI
1. In the Menu bar, click Remote Control.
2. Under Options, click Power Control, and then select one of the following options:
Reset System—Gracefully restart the appliance. All operations on the appliance are
stopped, no new connections to the client or server are accepted, and all existing connec-
tions are closed before the appliance restarts. This is similar to a warm restart, such as by
entering the reboot command. The BMC does not reboot itself during this operation.
Power O System Immediate—Disconnect power to the appliance immediately, with-
out gracefully shutting down the appliance. The BMC continues to operate normally in this
© 1999-2019 Citrix Systems, Inc. All rights reserved. 150

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX Series and is the answer not in the manual?

Citrix ADC MPX Series Specifications

General IconGeneral
TypeApplication Delivery Controller
MemoryUp to 256 GB
Power SupplyRedundant
Product SeriesMPX
Ports10/25/40/100 Gbps Ethernet
Operating SystemCitrix ADC
ManagementCitrix ADM
Form FactorRack-mountable