mode to allow the user to remotely power on the appliance. This is the same as pushing
the power button until the unit powers o.
Power O System Orderly Shutdown—Gracefully shut down the appliance, and then
disconnect power to the appliance. Has the same eect as pressing the power button on
the back panel of the appliance for less than four seconds. All operations on the appli-
ance are stopped, no new connections to the client or server are accepted, and all existing
connections are closed before the appliance shuts down. The BMC continues to operate
normally in this mode to allow the user to remotely power on the appliance. This is the
same as entering the shutdown command in the appliance shell.
Power On SystemTurn on the appliance. The BMC does not reboot itself during this
operation. This is the same as pushing the power button.
Power Cycle SystemTurn o the appliance, and then turn it back on. The BMC does not
reboot itself during this operation. This is the same as pushing the power button until the
unit powers o, and then pushing the power button to power on the unit.
3. Click Perform Action.
Perform a power cycle of the BMC
A warm restart, cold restart, or a power cycle of the appliance, using the power button, does not in-
clude power cycling the BMC. The BMC runs on standby power directly from the power supply. There-
fore, the BMC is not aected by any state of the power button on the appliance. The only way to power
cycle the BMC is to remove all power cords from the appliance for 60 seconds.
Perform power control operations on the BMC by using the appliance shell
When performing either a warm or cold restart of the BMC microcontroller, you cannot communicate
with the LOM port. Both actions restart the BMC but not the main CPU. To perform a warm restart of
LOM from the appliance, type:
ipmitool mc reset warm
Perform a warm restart remotely from another computer on the network, type
ipmitool U <bmc_gui_username> P <bmc_gui_password> H <bmc IP address> mc
reset warm
Perform a cold restart of the LOM from the appliance, type
ipmitool mc reset cold
© 1999-2019 Citrix Systems, Inc. All rights reserved. 151

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX Series and is the answer not in the manual?

Citrix ADC MPX Series Specifications

General IconGeneral
TypeApplication Delivery Controller
MemoryUp to 256 GB
Power SupplyRedundant
Product SeriesMPX
Ports10/25/40/100 Gbps Ethernet
Operating SystemCitrix ADC
ManagementCitrix ADM
Form FactorRack-mountable

Related product manuals