Citrix ADC MPX
Health Attribute Recommended Range
System Fan Speed (RPM) 6700–8600
System Fan 1 Speed (RPM) 6600–8500
System Fan 2 Speed (RPM) 6700–8500
CPU 0 Temperature (Celsius) 40–57
CPU 1 Temperature (Celsius) 35–45
Internal Temperature (Celsius) 30–49
Power Supply 1 Status NORMAL
Power Supply 2 Status NOT PRESENT–NORMAL
Wiping your data before sending the ADC appliance to Citrix
August 28, 2019
The configuration wipe scripts remove all customer proprietary information from a Citrix ADC appli-
ance before Return Merchandise Authorization (RMA) or return from evaluation. The scripts are de-
signed to give the customer a high level of confidence that all their information has been removed.
Caution: Running these scripts is dangerous. If something goes wrong during execution, the appli-
ance might be rendered unbootable and Citrix might have to reinstall the soware image. The config
wipe scripts remove everything on the box, including licenses, configuration, images, and scripts. Run
these scripts only aer understanding the consequences.
Supported Platforms
The script is supported on all Citrix ADC MPX appliances. The script is not supported on Citrix ADC SDX
appliances. Delete the VPX instances before returning the SDX appliance.
Required script files
The following script files must be present in the /flash/.recovery directory. They are required for suc-
cessfully wiping out the data.
rc.conf_wipe_subr
rc.flash_wipe_recover
© 1999-2019 Citrix Systems, Inc. All rights reserved. 165

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX Series and is the answer not in the manual?

Citrix ADC MPX Series Specifications

General IconGeneral
TypeApplication Delivery Controller
MemoryUp to 256 GB
Power SupplyRedundant
Product SeriesMPX
Ports10/25/40/100 Gbps Ethernet
Operating SystemCitrix ADC
ManagementCitrix ADM
Form FactorRack-mountable