Configure SNMP alerts on the LOM by using the GUI
1. Download the IPMI View utility from ftp://ftp.supermicro.com/utility/IPMIView/ and install it on
your computer. Use this utility to test the configuration. For more information, see the section
about configuring the alert settings in the IPMI View User Guide at http://supermicro.com.
2. Open the IPMI View utility.
3. In the LOM GUI, navigate to Configuration > Alerts, click Alert No 1, and then click Modify.
4. Select the severity level of the events for which to generate alerts.
5. Set Destination IP to the IP address at which you installed the IPMI View utility.
6. Optionally, to receive alerts by email, specify an email address. To avoid receiving email for
routine alerts, specify a severity higher than Informational.
7. Click Save.
8. The LOM starts sending alerts to the IPMI View utility within in a minute or two. Aer the IPMI
View utility starts receiving alerts from the LOM, reconfigure the destination IP address to point
to your SNMP Network Management Soware, such as HP OpenView.
Set up SNMP alerts on the LOM by using the Citrix ADC shell
To customize your filter and policy settings, see the IPMI Specification 2.0 rev. 1.1 documentation.
The latest IPMI specifications are available from the IPMI section of the Intel website:
http://www.intel.com/content/www/us/en/servers/ipmi/ipmi-specifications.html
Usually, customization in the SNMP Network Management Soware is the preferred method, because
it can be done one time at a central location. Therefore, the following settings send all events for all
sensors to the SNMP network managementsoware. These events are low traic events and therefore
do not result in any significant network usage.
Set up SNMP filters
The following commands set up SNMP to allow all events:
ipmitool raw 4 0x12 0x6 0x10 0x80 1 1 0 0xff 0xff 0xff 0xff 0xff 0xff 0xff
0 0xff 0 0 0xff 0 0 0xff 0
Set up a policy list
The following command creates a policy list for all sensors and events:
ipmitool raw 4 0x12 9 0x10 0x18 0x11 0x81
© 1999-2019 Citrix Systems, Inc. All rights reserved. 142

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Citrix ADC MPX Series and is the answer not in the manual?

Citrix ADC MPX Series Specifications

General IconGeneral
TypeApplication Delivery Controller
MemoryUp to 256 GB
Power SupplyRedundant
Product SeriesMPX
Ports10/25/40/100 Gbps Ethernet
Operating SystemCitrix ADC
ManagementCitrix ADM
Form FactorRack-mountable

Related product manuals