EasyManua.ls Logo

Citrix ADC MPX Series - Page 67

Citrix ADC MPX Series
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Citrix ADC MPX
RS232 serial Console Port.
10/100Base-T copper Ethernet Port (RJ45), also called the LOM port. You can use this port to
remotely monitor and manage the appliance independently of the Citrix ADC soware.
Two 10/100/1000Base-T copper Ethernet Management Ports (RJ45), numbered 0/1 and 0/2 from
le to right. These ports are used to connect directly to the appliance for system administration
functions.
Network Ports. Twelve copper or fiber 1G SFP ports and twenty-four 10G SFP+ ports.
The following figure shows the back panel of the MPX 24100/24150 appliances.
Figure 2. Citrix ADC MPX 24100/24150, back panel
The following components are visible on the back panel of the MPX 24xxx appliances:
Non-maskable interrupt (NMI) Button, used at the request of Technical Support to initiate a core
dump. To press this red button, which is recessed to prevent unintentional activation, use a pen,
pencil, or other pointed object. The NMI Button is also available remotely over the network in
the LOM GUI, in the Remote Control menu.
System status LED, which indicates the status of the appliance, as described in Common hard-
ware components.
Note: On an
MPX 24100/24150 appliance running LOM firmware version 3.22, the system status LED indicates
an error (continuously glows RED) even though the appliance is functioning properly.
Four power supplies, each rated at 750 watts, 100-240 volts. A minimum of two power supplies
are required for proper operation. The extra power supplies act as backup. Each power supply
has an LED that indicates the status of the power supply, as described in Common hardware
components.
© 1999-2019 Citrix Systems, Inc. All rights reserved. 67

Table of Contents

Related product manuals