302
INJECTION
CHECKS: EXHAUST GASES RECYCLING CIRCUIT
Tool.
[1] Manual pressure-vacuum pump : FACOM DA 16
IMPERATIVE: Respect the safety and cleanliness requirements.
EGR valve.
Connect tool [1] on the capsule take-off (2).
Apply a vacuum of approx. 0,6 bar several times to activate the rod «a».
In abruptly suppressing the vacuum, the valve should click and lock itself back on its seating.
Regulation electrovalve (EGR).
Check to be performed between the electrovalve (1) and the EGR valve (2).
Link the tool [1] in series, between the electrovalve (1) and the capsule (2).
Compare the values noted with those in the table below.
Engine speed (rpm) Vacuum value
780 0,5 bar
2500 0 bar
B1HP1K6D
Engines: 8HX - 8HZ
XSARA