Page 16 WS2H and WS3 Manual
SETTING TIME OF DAY
SET TIME
Accessed by pressing Set Clock while in the User Screens. Use UP and DOWN
arrows to scroll hours. AM/PM alternates at midnight.
RETURN TO
NORMAL OPERATION
• REGEN TODAY
- Flashing indicates a regeneration has been manually set and can be turned off
by pressing and releasing the REGEN button
- A solid display indicates the regeneration has been scheduled by input
requirements and can’t be manually turned off
NOTIFICATIONS
• REGEN START / REGEN HOLD
- The display will ash “REGEN” or “REGEN HOLD”, depending on settings, to
indicate an external switch closure to the Aux. Input
• HIGH USAGE
- Screen ashes indicating setpoint was reached when using relay outputs to
signal high water usage. All LED lights ash and the relay with that setpoint
closes.
• Screen and the relay are re-set by pressing any button
• System operates as normal behind the indicator screen.
- Only active if Timer 2 or Timer 3 is set to “Day & Gal” or “Day & Gal & System”
• NUMBER OF UNITS ERROR
- The master unit of a system would ash an error screen alerting of a loss of
communication with a unit
- Check for proper operation and connectivity of the unit speci ed as lost
communications
- Pressing any button will return the user to the # units set up screen to correct /
verify the value of units in the system. Exiting will re-establish communications
- Each unit of the system will regenerate, based on its settings, with hard water
bypass
ERRORS
• FUNCTIONAL ERROR
- “Error” and its code alternate on the display
- The unit attempts to return to service but will not
regenerate until the error is cleared
- See troubleshooting section for a description of
possible error codes.