WS2H and WS3 Manual Page 61
Problem Possible Cause Solution
24. Err – 17002 = MAV for
Separate Source valve
motor ran too short while
trying to  nd proper park
position
a. Foreign material is lodged in MAV
for separate source valve
b. Mechanical binding
a. Open up MAV for separate source
and check for foreign material. Press
NEXT and REGEN buttons for about 3
seconds to resynchronize software with
piston position.
b. Check poppet drive assembly or piston
and seal/ stack assembly, check
reduction gears, drive gear interface,
and check MAV for separate source
black drive pinion on motor. Press
NEXT and REGEN buttons for about 3
seconds to resynchronize software with
piston position.
25. Err – 18000 = Reset was
performed, this error
code will display in the
diagnostics under the error
log
a. Press the NEXT and REGEN
buttons for about 3 seconds to
resynchronize software with piston
position.
26. Err – 18001 = Power loss,
this error code will display in
the diagnostics under error
log
a. When power is lost a signal is sent
to log the power loss
27. Err – 18002 = Power
restored, this error code will
display in the diagnostics
under error log
a. When power is restored a signal
is sent to log the power being
restored